Search results for "Goldmann applanation tonometry"

showing 7 items of 7 documents

Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields

1996

Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtyAdolescentgenetic structuresSiliconesOcular hypertensionGlaucomaSensitivity and SpecificityGoldmann applanation tonometryChemical disinfectionTonometry Ocularchemistry.chemical_compoundSiliconeDouble-Blind MethodOphthalmologymedicineHumansChildDisposable EquipmentIntraocular PressureAgedAged 80 and overAlternative methodsbusiness.industryReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologychemistryEvaluation Studies as TopicInfertilityFemaleOcular Hypertensionsense organsbusinessOphthalmology
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers

2005

Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…

AdultMaleIntraocular pressuremedicine.medical_specialtyClinical Science - Scientific ReportsPalpationGoldmann applanation tonometryTonometry OcularCellular and Molecular NeuroscienceInterquartile rangeOphthalmologyHealthy volunteersHumansMedicineIn patientIntraocular PressureObserver VariationReproducibilityPalpationmedicine.diagnostic_testbusiness.industryReproducibility of ResultsEquipment DesignSensory SystemsOphthalmologyQuartileFemalebusinessBritish Journal of Ophthalmology
researchProduct

The relationship between central corneal thickness and Goldmann applanation tonometry

2003

The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…

AdultMaleApplanation tonometrymedicine.medical_specialtyIntraocular pressureAdolescentgenetic structuresGoldmann applanation tonometryCorneaTonometry OcularOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedAnalysis of Variancebusiness.industryCorneal TopographyMiddle Agedeye diseasesLarge sampleOphthalmologyRegression AnalysisOptometryFemalesense organsbusinessOptometryClinical and Experimental Optometry
researchProduct

Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial

2023

AimTo investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS).MethodsProspective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor’s safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tono…

Intraocular pressuremedicine.medical_specialtyOpen angle glaucomaDRAINAGEmedicine.medical_treatmentGlaucomaCANALOPLASTYGOLDMANN APPLANATION TONOMETRYTERMGoldmann applanation tonometrytreatment surgeryCellular and Molecular NeuroscienceDYNAMIC CONTOUR TONOMETRYOphthalmologyMaximum differenceGlaucoma surgerymedicineDevice migrationTrial registrationHEALTHYbusiness.industrymedicine.diseaseSensory SystemsOphthalmologyglaucomaIMPLANTATIONbusinessintraocular pressureBritish Journal of Ophthalmology
researchProduct

Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis

2004

PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…

AdultApplanation tonometrymedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SitueducationKeratomileusisGoldmann applanation tonometryTonometry OcularmedicineHumansPostoperative PeriodProspective StudiesIntraocular Pressurebusiness.industrySignificant differenceLASIKhumanitieseye diseasesSurgeryGoldmann tonometryOphthalmologyHyperopiaTreatment OutcomeRetreatmentsense organsbusinessCornea
researchProduct

Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.

2016

AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and ORA measurements performed on each eye differed depending on the randomly allocated investigation scheme. Central corneal thickness (CCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were assessed with Pentacam before and after the repeated GAT/ORA measurements. RESULTS There was no sta…

Intraocular pressuregenetic structuresEye DiseasesPhysiologyGlaucomalcsh:MedicineWalkingGoldmann applanation tonometryCornea0302 clinical medicineMedicine and Health SciencesMedicineBiomechanicslcsh:ScienceMultidisciplinaryOphthalmic ProceduresDrugsMiddle AgedFemaleAnatomyResearch ArticleAdultmedicine.medical_specialtyOcular AnatomySurgical and Invasive Medical ProceduresCorneal hysteresis03 medical and health sciencesTonometry OcularOcular SystemOphthalmologyHumansPain ManagementIn patientIntraocular PressureAgedAnestheticsPharmacologybusiness.industryBiological Locomotionlcsh:RBiology and Life SciencesGlaucomamedicine.diseaseeye diseasesOphthalmologyCase-Control Studies030221 ophthalmology & optometryEyeslcsh:Qsense organsbusinessHead030217 neurology & neurosurgeryPloS one
researchProduct